Comfort
Comfort class
Based on the peak acceleration limit value the comfort class can be defined as:
| Comfort class | Degree of comfort | |
|---|---|---|
| CL1 | Maximumm | |
| CL2 | Medium | |
| CL3 | Minimum | |
| CL4 | Intolerable |
Based on the crest factor a further evaluation must be required if:
| Crest factor () | Evaluation required |
|---|---|
| Basic | |
| Detailed |
Recommended limit values for floor vibration serviceability based on the peak acceleration and the Maximum Transient Vibration Value (MTVV) according to:
-
BS 6472-1:2008: Guide to Evaluation of Human Exposure to Vibration in Buildings: Vibration Sources Other Than Blasting. British Standards Institution, 2008
-
A. L. Smith, S. J. Hicks, and P. J. Devine. Design of floors for vibration: A new approach. Steel Construction Institute Ascot, Berkshire, UK, 2007.
are given in the following table:
| Floor type | MTVV | |
|---|---|---|
| Hospital | 0.005 | 0.007 |
| Residential | 0.010 | 0.014 |
| Office | 0.020 | 0.028 |
| Workshops | 0.040 | 0.057 |